Datos de entrada y compatibilidad de dispositivos
v1.0.7
Los siguientes dispositivos son compatibles con RetinaLyze AI
Si su dispositivo no está en la lista, por favor contáctenos para obtener más información sobre la calibración y el soporte del dispositivo.
FABRICANTE | DISPOSITIVO | ¿RETINALYZE RD/DMAE COMPATIBLE? | ¿RETINALYZE GLAUCOMA COMPATIBLE? | ¿RETINALYZE OCT COMPATIBLE? | SOFTWARE SOPORTADO |
|---|---|---|---|---|---|
Canon | CR1 | YES | YES | - | RX |
CR2-AF | YES | YES | - | ||
CR-DGi | YES | YES | - | ||
CX-1 | YES | YES | - |
| |
CenterVue / iCare | DRS | YES | YES | - |
|
DRS Plus | NO | NO | - |
| |
Eidon | NO | NO | - |
| |
Cobra | HD | YES | YES | - | Phoenix, Phoenix v3.0 |
Retina 400 | YES | YES | - | ||
VX620 | YES | YES | - | ||
CrystalVue | FundusVue / NFC-700 | YES | YES | - |
|
Easyscan | Easyscan | NO | NO | - |
|
Essilor | Retina 800 | YES | YES | - |
|
Retina 550 | YES | YES | - | AnaEyes | |
Horus | DEC 100 | YES | YES | - | Image Management Platform SA1 |
DEC 200 | YES | YES | - | ||
Huvitz | HFC-1 | YES | YES | - |
|
HOCT-1 1F | YES | YES | NOT VERIFIED |
| |
Kowa | Nonmyd 7 | YES | YES | - | VK-2 |
Nonmyd L-D | YES | YES | - | ||
Microclear | Luna Plus | NOT VERIFIED | YES | - |
|
Nidek | AFC210 | YES | YES | - | Navis-EX, Navis Lite |
AFC330 | YES | YES | - | Navis-EX, Navis Lite | |
RS-330 | YES | YES | YES | Navis-EX | |
Optomed | Aurora | NO | YES | - |
|
Smartscope M5 | NO | YES | - |
| |
Optopol | REVO FC | YES | YES | YES | S-OCT v9.5.0 |
REVO NX 130 | - | - | YES | ||
REVO 80 | - | - | YES | ||
REVO 60 | - | - | YES | ||
Optos | Daytona | NO | NO | - |
|
PHELCOM | Eyer | NOT VERIFIED | YES | - |
|
Eyer II | YES | YES | - |
| |
Remidio | FOP NM-10 | NO | YES | - |
|
Rodenstock | Fundusscope | YES | YES | - |
|
Sun Kingdom | SK650A | YES | YES | - |
|
Tomey | TFC-1000 | YES | YES | - |
|
TFC-1000 (v2) | YES | YES | - |
| |
Topcon | TRC-50DX | YES | YES | - | EZ Capture, 3DOCT, IMAGEnet i-base 3, IMAGEnet 6, Harmony |
3D OCT-1000 | NOT VERIFIED | NO | NOT VERIFIED | ||
NW200 | YES | YES | - | ||
NW300 | YES | YES | - | ||
NW400 | YES | YES | - | ||
NW500 | YES | YES | - | ||
NW6SF | YES | YES | - | ||
NW8F | YES | YES | - | ||
Triton | YES | YES | YES | 3DOCT, Imagenet 6, Harmony | |
Maestro | YES | YES | YES | 3DOCT, Imagenet 6, Harmony | |
Maestro 2 | YES | YES | YES | 3DOCT, Imagenet 6, Harmony | |
Visionix | Nexy | YES | YES | - |
|
VX650 | YES | YES | - |
| |
VOLK | Pictor Plus | NOT VERIFIED | YES | - |
|
Zeiss | Pro NM | YES | YES | - |
|
Visucam 200 | YES | YES | - |
| |
Visucam 224 | YES | YES | - |
| |
Visucam 500 | YES | YES | - |
| |
Visucam 524 | YES | YES | - |
| |
Visucam Meditec A6 | NOT VERIFIED | NOT VERIFIED | - |
|
Cámaras de retina
¿Qué formatos de archivo se pueden utilizar con los algoritmos de fondo de ojo/imagen retiniana de RetinaLyze?
Los algoritmos RetinaLyze actualmente admiten tipos de archivos .jpg/.jpeg y DICOM.
¿Qué tipo de imágenes de fondo de ojo se pueden utilizar con los algoritmos de RetinaLyze?
Uso de imágenes centradas en la mácula frente a imágenes centradas en ONH
Se pueden usar imágenes centradas en la mácula o el nervio óptico, pero cada cámara de fondo de ojo siempre debe usarse de la misma manera (si se usa RetinaLyze Glaucoma).
Ángulo de visión mín./máximo (por ejemplo, 30-200 grados)
El ángulo debe ser de al menos 30 grados. No hay un ángulo de visión máximo.
Ángulo de visión (específico para el glaucoma RetinaLyze)
La imagen siempre debe incluir todo el nervio óptico. Cada cámara de fondo de ojo debe utilizarse siempre con la misma amplificación angular.
¿Uso de imágenes de luz blanca/SLO?
Se admiten algunas imágenes SLO. No deben utilizarse imágenes obtenidas con iluminación monocromática ni con sistemas de escaneo confocal.