Input data and device compatibility
v1.0.5
Supported devices
The following devices are supported by the RetinaLyze AI. Yellow relates to fundus/retinal image based AI, while blue indicates OCT based AI.
If your device is not on the list, please contact us to find out more about calibration and device support.
MANUFACTURER | DEVICE | RETINALYZE DR/AMD SUPPORTED? | RETINALYZE GLAUCOMA SUPPORTED? | RETINALYZE OCT SUPPORTED? | SUPPORTED SOFTWARE |
|---|---|---|---|---|---|
Canon | CR1 | YES | YES | - | RX |
CR2-AF | YES | YES | - | ||
CR-DGi | YES | YES | - | ||
CX-1 | YES | YES | - |
| |
CenterVue / iCare | DRS | YES | YES | - |
|
DRS Plus | NO | NO | - |
| |
Eidon | NO | NO | - |
| |
Cobra | HD | YES | YES | - | Phoenix, Phoenix v3.0 |
Retina 400 | YES | YES | - | ||
VX620 | YES | YES | - | ||
CrystalVue | FundusVue / NFC-700 | YES | YES | - |
|
Easyscan | Easyscan | NO | NO | - |
|
Essilor | Retina 800 | YES | YES | - |
|
Retina 550 | YES | YES | - | AnaEyes | |
Horus | DEC 100 | YES | YES | - | Image Management Platform SA1 |
DEC 200 | YES | YES | - | ||
Huvitz | HFC-1 | YES | YES | - |
|
HOCT-1 1F | YES | YES | NOT VERIFIED |
| |
Kowa | Nonmyd 7 | YES | YES | - | VK-2 |
Nonmyd L-D | YES | YES | - | ||
Microclear | Luna Plus | NOT VERIFIED | YES | - |
|
Nidek | AFC210 | YES | YES | - | Navis-EX, Navis Lite |
AFC330 | YES | YES | - | Navis-EX, Navis Lite | |
RS-330 | YES | YES | YES | Navis-EX | |
Optomed | Aurora | NO | YES | - |
|
Smartscope M5 | NO | YES | - |
| |
Optopol | REVO FC | YES | YES | YES | S-OCT v9.5.0 |
REVO NX 130 | - | - | YES | ||
REVO 80 | - | - | YES | ||
REVO 60 | - | - | YES | ||
Optos | Daytona | NO | NO | - |
|
PHELCOM | Eyer | NOT VERIFIED | YES | - |
|
Eyer II | YES | YES | - |
| |
Remidio | FOP NM-10 | NO | YES | - |
|
Rodenstock | Fundusscope | YES | YES | - |
|
Sun Kingdom | SK650A | YES | YES | - |
|
Tomey | TFC-1000 | YES | YES | - |
|
TFC-1000 (v2) | YES | YES | - |
| |
Topcon | TRC-50DX | YES | YES | - | EZ Capture, 3DOCT, IMAGEnet i-base 3, IMAGEnet 6, Harmony |
3D OCT-1000 | NOT VERIFIED | NO | NOT VERIFIED | ||
NW200 | YES | YES | - | ||
NW300 | YES | YES | - | ||
NW400 | YES | YES | - | ||
NW500 | YES | YES | - | ||
NW6SF | YES | YES | - | ||
NW8F | YES | YES | - | ||
Triton | YES | YES | YES | 3DOCT, Imagenet 6, Harmony | |
Maestro | YES | YES | YES | 3DOCT, Imagenet 6, Harmony | |
Maestro 2 | YES | YES | YES | 3DOCT, Imagenet 6, Harmony | |
Visionix | Nexy | YES | YES | - |
|
VX650 | YES | YES | - |
| |
VOLK | Pictor Plus | NOT VERIFIED | YES | - |
|
Zeiss | Pro NM | YES | YES | - |
|
Visucam 200 | YES | YES | - |
| |
Visucam 224 | YES | YES | - |
| |
Visucam 500 | YES | YES | - |
| |
Visucam 524 | YES | YES | - |
| |
Visucam Meditec A6 | NOT VERIFIED | NOT VERIFIED | - |
|
Retinal cameras
What file formats can be used with the RetinaLyze fundus/retinal image algorithms?
The RetinaLyze algorithms currently support both .jpg/.jpeg and DICOM file types.
What type of fundus images can be used with the RetinaLyze algorithms?
Use of Macula-centered vs. ONH centered imagery
Images centered on the macula or optic nerve may be used, but each fundus camera should always be used in the same way (if RetinaLyze Glaucoma is used).
Min/max angle of view (e.g. 30-200 degrees)
The angle should be at least 30 degrees. There is no maximum angle of view.
Angle of view (Specific for RetinaLyze Glaucoma)
The image must always include the entire optic nerve. Each fundus camera should always be used with the same angular amplification.
Use of White-light/SLO imagery?